Leave Your Message
Products Categories
Featured Products

SP-6801A Gas Chromatograph

The SP-6801A Gas Chromatograph is a reliable single-detector GC system designed for routine laboratory analysis. Available with FID, TCD, or ECD detector configurations, it offers precise temperature control, 9-step temperature programming, and an intuitive color touchscreen interface. Its stable performance, compact design, and cost-effective operation make it ideal for environmental monitoring, food safety testing, petrochemical analysis, and scientific research.

  • Supports FID, TCD, and ECD detector configurations
  • 9-step temperature programming for flexible analysis
  • Intelligent rear-door oven design for efficient cooling
  • Color touchscreen interface for easy operation
  • High temperature control precision of ±0.1°C
  • Stable analytical performance with low noise and drift
  • Compact structure and reliable long-term operation
  • Suitable for routine and research laboratory applications

    Product Advantage

    Flexible Detector Selection

    The SP-6801A can be configured with FID, TCD, or ECD detectors to meet a wide range of analytical requirements.

    Accurate Temperature Control

    The oven temperature range extends from Ambient +3°C to 399°C, ensuring reliable separation and repeatable results.

    Efficient Cooling Performance

    The intelligent rear-door system reduces cooling time and improves laboratory productivity.

    User-Friendly Operation

    A modern color touchscreen simplifies method setup, operation, and monitoring.

    Cost-Effective Solution

    Combining stable performance and flexible configuration, the SP-6801A provides excellent value for laboratories.

    Product Specifications

    Oven System
    Parameter Specification
    Temperature Range Ambient +3°C to 399°C
    Temperature Control Precision ±0.1°C
    Temperature Accuracy ±3%
    Cooling Speed 250°C to 50°C in approximately 8 minutes
    Temperature Programming 9-Step Program
    FID Detector
    Detection Limit ≤1×10⁻¹¹ g/s
    Noise ≤2×10⁻¹⁴ A
    Drift ≤2×10⁻¹³ A/30min
    Linear Range ≥10⁶
    TCD Detector
    Sensitivity ≥4000 mV·mL/mg
    Noise ≤0.02 mV
    Drift ≤0.2 mV/30min
    Linear Range ≥10⁴
    ECD Detector
    Detection Limit ≤1×10⁻¹³ g/mL
    Noise ≤0.04 mV
    Drift ≤0.3 mV/30min
    Linear Range ≥10³

    Application Areas

    • Environmental Monitoring
    • Food Safety Testing
    • Petrochemical Analysis
    • Pesticide Residue Analysis
    • Chemical Manufacturing
    • Research Laboratories
    • Quality Control Laboratories
    • Industrial Gas Analysis

    description2

    FAQ

    • 1.What detector options are available for the SP-6801A?

    • 2. Is the SP-6801A suitable for food safety testing?

    • 3.Does the instrument support temperature programming?

    • 4. What industries commonly use this gas chromatograph?

    • 5. What is the maximum oven temperature?

    Leave Your Message