- Lab Instruments
- Analytical Instruments
- Anti-Drone Equipment
- Micro/Nano Fabrication
- CBRNE Detection
- High-Power Laser & Devices
- Other Technical Products
0102030405
LSPEC-S30 Acoustic Thermal Imager from China Suppliers - High-Efficiency Detection by Factory for Partial Discharge and Temperature Measurement
Product Features
- 1 162 digital noise reduction microphone array, handheld structure design, integrating infrared thermal imaging and acoustic imaging.
- 2 5-inch ultra-clear display with split-screen function to display the device under test on the same screen.
- 3 Adjustable frequency detection range from 2 kHz to 100 kHz covers the core frequency band of partial discharge and shields interference signals.
- 4 Detection distance 0.3 m ~ 150 m, suitable for long-distance line inspection.
- 5 Identifies discharge types such as suspension, corona and creeping, and displays PRPD diagrams.
- 6 Supports dynamic range adjustment and single/multi-source switching.
- 7 Convenient browsing, viewing and output.
- 8 Small size and light weight: microphone array surface size is only 70 mm and weighs only 0.98 kg.
- 9 Replaceable battery & ultra-long battery life: removable battery design, single battery lasts no less than 3.5 hours. Equipped with 2 spare batteries to easily meet a full day's work needs.
Product Parameters
| Items | Specifications | |
| Sonic Imaging | Acoustic detection mode | Partial discharge detection, leak detection |
| Microphone | 162 high-sensitivity digital microphones | |
| Sensitivity | -26 dBFS@1 kHz 94dB | |
| Imaging sound pressure level range | 20 dB ~ 120 dB | |
| Imaging frequency range | 2 kHz ~ 100 kHz | |
| Sampling rate | 200 kHz | |
| Positioning error | <0.05 m@1 m, 40 kHz | |
| Lateral resolution | <0.30 m@1 m, 40 kHz | |
| Dynamic Range | >10 dB@40 kHz | |
| Minimum leakage | 0.5 m, 0.5 MPa, minimum detectable leak is 0.15 ml/s; 1 m, minimum detectable leak of 0.2 ml/s at 0.5 MPa |
|
| Test distance | 0.3 m ~ 150 m | |
| Image frame number | 25 FPS | |
| Visible Light | Visible light pixels | 13 megapixels |
| Viewing angle | 62°(H) × 53°(V) | |
| Infrared Imaging | Infrared resolution | 640 × 512 |
| Field of view / focal length | 29.3°(H) × 23.4°(V), 37.5°(D) / 15 mm | |
| Temperature measurement range | -20 ℃ ~ +150 ℃, 100 ~ 550 ℃ | |
| Temperature measurement accuracy | ±2 °C or ±2% of reading (whichever is greater) | |
| Basic Parameters | Screen size | 5.0-inch widescreen, resolution 720 × 1280 |
| Data storage | Built-in 64 GB storage space, supports SD card expansion | |
| Connector |
Type-C: charging, data transmission TF card slot: expand storage capacity SIM card slot: insert 4G/5G network communication card 3.5 mm headphone jack: external headphone monitoring |
|
| Wireless connectivity | Support WiFi, Bluetooth | |
| Trigger shortcut keys | Support fast shooting | |
| Charger | Supports fast charging, line charging 5 V/3 A, dock charging 12 V/5 A | |
| Battery | Removable battery 4900 mAh 7.26 V | |
| Battery endurance | Full load single battery life 3.5 hours | |
| Operating temperature | -20 ℃ ~ 50 ℃ | |
| Volume / Mass | 286 (H) × 154 (W) × 83 (D) mm, 0.98 kg | |
Application Areas
⚡
Suitable for detecting partial discharge of electrical equipment in substations or on transmission and distribution lines, and locating gas leakage points.
Frequently Asked Questions
Q
What is the maximum detection distance of this acoustic imaging device?
The device supports a detection distance range of 0.3 m to 150 m, making it well-suited for both close-range inspections and long-distance transmission line surveys.
Q
What types of partial discharge can this device identify?
The device can identify multiple discharge types including suspension discharge, corona discharge, and creeping discharge. It also displays PRPD (Phase-Resolved Partial Discharge) diagrams to assist in accurate diagnosis.
Q
How long does the battery last, and can it be replaced in the field?
The device uses a removable 4900 mAh battery that provides at least 3.5 hours of full-load operation. It comes with 2 spare batteries, allowing users to easily swap batteries and work through an entire day without interruption.
Q
What is the frequency detection range, and why does it matter?
The adjustable frequency range spans from 2 kHz to 100 kHz. This covers the core frequency band associated with partial discharge activity while effectively filtering out background interference signals, ensuring more accurate and reliable detection results.
Q
Does the device support infrared thermal imaging in addition to acoustic imaging?
Yes. The device integrates infrared thermal imaging with a resolution of 640×512 and a temperature measurement range of -20 ℃ to +150 ℃ (and 100 ℃ to 550 ℃ for high-temperature scenarios), alongside acoustic imaging and visible light camera — all in a single handheld unit.
Q
What connectivity and storage options does the device offer?
The device includes 64 GB built-in storage with SD card expansion support. Connectivity options include WiFi, Bluetooth, Type-C (data & charging), TF card slot, SIM card slot (4G/5G), and a 3.5 mm headphone jack for audio monitoring — providing comprehensive data management and communication flexibility.


Phone
Facebook
Youtube