- Lab Instruments
- Analytical Instruments
- Anti-Drone Equipment
- Micro/Nano Fabrication
- CBRNE Detection
- High-Power Laser & Devices
- Other Technical Products
0102030405
LSPEC 5010 Portable Fourier Transform Infrared Spectrometer - Top China Suppliers & Factory Solutions for Accurate Measurements
Product Features
-
Wide Detection Range Integrates multiple detection technologies, covering common solid, liquid, and gaseous forms of chemical warfare agents and toxic and hazardous substances.
-
Low False Alarm Rate Combines the recognition features of multiple sensors and employs an advanced array-based pattern recognition algorithm to minimize the false alarm rate.
-
Low Detection Limit The detection range for solid and liquid samples is above 1%, and the detection range for gaseous samples is between ppb and ppm levels.
-
Easy to Operate Highly user-friendly design for straightforward and efficient operation in field or laboratory environments.
-
Fast Response Solid and liquid samples are detected within 10 seconds, and gaseous samples are detected within 30 seconds.
Product Parameters
| Project | Technical Parameters | |
| Types of Tests | Thousands of chemical substances or war agents (can be expanded according to user needs). | |
| Spectral Range | 600 cm⁻¹ ~ 5000 cm⁻¹ | |
| Signal-to-Noise Ratio | ≥20000:1 (1 minute sampling time, spectral resolution 4 cm⁻¹) | |
| Resolution | 2 cm⁻¹, with options from 1 cm⁻¹ to 8 cm⁻¹ | |
| Wavenumber Accuracy | ≤0.0005 cm⁻¹ @ 2000 cm⁻¹ | |
| Transmittance Accuracy | Better than 0.1%T | |
| Optical System | All-gold-plated optical system, ZnSe beam splitter | |
| Corner Mirror Interferometer | Compact bicorner mirror torsion Michelson interferometer | |
| Detector | High Sensitivity DLATGS | |
| Detection Method | Optional accessories include a transmissive type, ATR, and an absorption cell. | |
| Optical Path of Absorption Cell | High-temperature absorption tank 4.8m | |
| ATR Annex | ZnSe total internal reflection prism | |
| Power Consumption | ≤30W (excluding absorption tank heating) | |
| Communication Interface | RS422 | |
| Dimensions & Weight (Transmissive Accessories) | ≤310mm × 220mm × 130mm | |
Frequently Asked Questions
Q
What types of substances can this device detect?
The device can detect thousands of chemical substances and warfare agents, including common solid, liquid, and gaseous forms of chemical warfare agents and toxic hazardous substances. The detection library can also be expanded according to specific user needs.
Q
How quickly does the device provide detection results?
The device delivers rapid results: solid and liquid samples are detected within 10 seconds, while gaseous samples are detected within 30 seconds, making it suitable for time-sensitive field operations.
Q
What is the detection sensitivity for gaseous samples?
For gaseous samples, the detection limit falls within the ppb to ppm concentration range, enabling identification of trace-level hazardous substances in the air. For solid and liquid samples, the detection range is above 1%.
Q
What detection accessories are available for this instrument?
The instrument supports multiple optional accessories, including a transmissive type, an ATR (Attenuated Total Reflectance) attachment with a ZnSe total internal reflection prism, and a high-temperature absorption cell with a 4.8m optical path, allowing flexible configuration for different sample types.
Q
How does the device minimize false alarms?
The device integrates recognition features from multiple sensors and applies an advanced array-based pattern recognition algorithm. This multi-sensor fusion approach significantly reduces the false alarm rate compared to single-sensor systems.
Q
What are the power consumption and communication interface specifications?
The device consumes ≤30W of power (excluding absorption tank heating), making it energy-efficient for portable or field use. It communicates via an RS422 interface for reliable data transmission in demanding environments.